{"product_id":"pentair-pentek®-smc-crp5021-submersible-motor-control-box-5-hp-230v-single-phase-copy","title":"Franklin Electric 513431 – NCP-S2332V230P1-2, Simplex Control Panel (230V, 1PH, FLA: 23-32 )","description":"\u003cdiv class=\"product-hero-titles d-none d-md-block\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFranklin Electric 513431 Simplex Solids Handling Control Panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eModel NCP-S2332V230P1-2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, is a reliable and durable control solution engineered specifically for single-phase NC Series submersible solids handling pumps. Operating at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this advanced pump control panel is designed to provide dependable pump management and system protection for municipal, commercial, industrial, and wastewater applications. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eItem 513431 \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003epanel features built-in motor starting components, thermal cut-out protection, seal fail indication circuitry, adjustable overload protection, and an integrated audible\/visual alarm system to help minimize downtime and protect critical pumping equipment. Housed in a rugged \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNEMA 4X indoor\/outdoor enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the NCP-S2332V230P1-2 offers superior durability and corrosion resistance, making it ideal for demanding lift station and sewage pump installations. If you're looking for a high-quality \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFranklin Electric simplex pump control panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase solids handling pump system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the 513431 delivers the performance, reliability, and long-term value professionals depend on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e** Please Note:  Image is a stock photo and may not match exactly **\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for the NC Series Solids Handling Pumps. Single-phase panels include start components in the panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShort circuit and adjustable overload protection\u003c\/li\u003e\n\u003cli\u003eSeal fail indication circuitry with built-in control and alarm options\u003c\/li\u003e\n\u003cli\u003eThermal cut-out circuitry\u003c\/li\u003e\n\u003cli\u003eAudible alarm with silence switch\u003c\/li\u003e\n\u003cli\u003eStatus beacon with multi-color ─ green normal or pump run, red alarm\u003c\/li\u003e\n\u003cli\u003eSeparate alarm and control auto reset fuses\u003c\/li\u003e\n\u003cli\u003eHand \/ Off \/ Auto switch\u003c\/li\u003e\n\u003cli\u003eIEC motor contactor\u003c\/li\u003e\n\u003cli\u003e\"Check-It\" feature displays all float and pump statuses and allows manual pump operation\u003c\/li\u003e\n\u003cli\u003eWaterproof NEMA 4X Enclosure\u003c\/li\u003e\n\u003cli\u003eUL 508A listing\u003c\/li\u003e\n\u003cli\u003eLockable latch\u003c\/li\u003e\n\u003cli\u003eAlarm flasher\u003c\/li\u003e\n\u003cli\u003eAuxiliary alarm contacts\u003c\/li\u003e\n\u003cli\u003eRedundant off float\/low level alarm provision\u003c\/li\u003e\n\u003cli\u003eBuilt-in PCB surge protection\u003c\/li\u003e\n\u003cli\u003eChange configurations: float error ─ redundant pump start, automatic or manual alarm reset, low alarm and seal alarm options\u003c\/li\u003e\n\u003cli\u003eMore options available upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1a7omtf\" data-start=\"80\" data-end=\"110\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"84\" data-end=\"110\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"112\" data-end=\"644\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"112\" data-end=\"145\"\u003e\n\u003ctr data-start=\"112\" data-end=\"145\"\u003e\n\u003cth data-start=\"112\" data-end=\"132\" data-col-size=\"sm\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"114\" data-end=\"131\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"132\" data-end=\"145\" data-col-size=\"sm\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"134\" data-end=\"143\"\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"180\" data-end=\"644\"\u003e\n\u003ctr data-start=\"180\" data-end=\"205\"\u003e\n\u003ctd data-start=\"180\" data-end=\"196\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"182\" data-end=\"195\"\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"196\" data-end=\"205\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"206\" data-end=\"235\"\u003e\n\u003ctd data-start=\"206\" data-end=\"219\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"208\" data-end=\"218\"\u003ePhases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"219\" data-end=\"235\"\u003eSingle-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"236\" data-end=\"261\"\u003e\n\u003ctd data-start=\"236\" data-end=\"250\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"238\" data-end=\"249\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"250\" data-end=\"261\" data-col-size=\"sm\"\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"262\" data-end=\"310\"\u003e\n\u003ctd data-start=\"262\" data-end=\"296\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"264\" data-end=\"295\"\u003eStart Capacitor Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"296\" data-end=\"310\"\u003e270–324 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"311\" data-end=\"355\"\u003e\n\u003ctd data-start=\"311\" data-end=\"343\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"313\" data-end=\"342\"\u003eRun Capacitor Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"343\" data-end=\"355\"\u003e47–53 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"356\" data-end=\"422\"\u003e\n\u003ctd data-start=\"356\" data-end=\"400\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"358\" data-end=\"399\"\u003eStart Relay Pickup \/ Drop Out Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"400\" data-end=\"422\"\u003e295–324V \/ 60–135V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"423\" data-end=\"455\"\u003e\n\u003ctd data-start=\"423\" data-end=\"449\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"425\" data-end=\"448\"\u003eSubTrol Heat Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"449\" data-end=\"455\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"456\" data-end=\"480\"\u003e\n\u003ctd data-start=\"456\" data-end=\"474\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"458\" data-end=\"473\"\u003eCheck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"474\" data-end=\"480\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"481\" data-end=\"520\"\u003e\n\u003ctd data-start=\"481\" data-end=\"500\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"483\" data-end=\"499\"\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"500\" data-end=\"520\"\u003eIndoor \/ Outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"521\" data-end=\"571\"\u003e\n\u003ctd data-start=\"521\" data-end=\"555\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"523\" data-end=\"554\"\u003eElectrical Agency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"555\" data-end=\"571\"\u003ecULus Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"572\" data-end=\"606\"\u003e\n\u003ctd data-start=\"572\" data-end=\"601\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"574\" data-end=\"600\"\u003eMinimum Order Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"601\" data-end=\"606\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"607\" data-end=\"644\"\u003e\n\u003ctd data-start=\"607\" data-end=\"631\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"609\" data-end=\"630\"\u003eStandard Warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"631\" data-end=\"644\"\u003e12 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Franklin Electric","offers":[{"title":"Default Title","offer_id":47770082607267,"sku":"513431","price":2085.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/2058\/5123\/files\/FEControlPanel.png?v=1781292534","url":"https:\/\/dadepump.com\/products\/pentair-pentek%c2%ae-smc-crp5021-submersible-motor-control-box-5-hp-230v-single-phase-copy","provider":"Dade Pump \u0026 Supply","version":"1.0","type":"link"}