Franklin Electric
Franklin Electric 513442 – NCP-S4865V460P3-2, Simplex Control Panel (200/230/460V, 3PH, FLA: 48-65 )
Franklin Electric 513442 – NCP-S4865V460P3-2, Simplex Control Panel (200/230/460V, 3PH, FLA: 48-65 )
SKU:513442
Couldn't load pickup availability
The Franklin Electric 513442 Simplex Solids Handling Control Panel, Model NCP-S4865V460P3-2, is a heavy-duty control solution engineered for reliable operation and advanced motor protection of NC Series three-phase submersible non-clog solids handling pumps. Designed for demanding municipal, commercial, industrial, and wastewater lift station applications, Item 513442 operates at 60 Hz, Three-Phase, and supports 200 VAC, 230 VAC, and 460 VAC power systems, providing exceptional flexibility across a wide range of installations. Built for pumps with a 48–65 full-load amp (FLA) range, this Franklin Electric simplex control panel features adjustable overload protection, seal fail indication circuitry, thermal cut-out monitoring, an integrated audible and visual alarm system, and a convenient Hand/Off/Auto selector switch for simplified operation and maintenance. The rugged NEMA 4X indoor/outdoor enclosure delivers superior corrosion resistance and long-term durability in harsh wastewater environments. For contractors, municipalities, and industrial facilities seeking a dependable three-phase simplex wastewater pump control panel, the Franklin Electric 513442 NCP-S4865V460P3-2 provides the professional-grade performance and reliability trusted throughout the water and wastewater industry.
** Please Note: Image is a stock photo and may not match exactly **
Designed for the 3-phase NC Series Submersible Solids Handling Pumps
Features & Benefits
- Short circuit and adjustable overload protection
- Seal fail indication circuitry with built-in control and alarm options
- Thermal cut-out circuitry
- Audible alarm with silence switch
- Status beacon with multi-color ─ green normal or pump run, red alarm
- Separate alarm and control auto reset fuses
- Hand / Off / Auto switch
- IEC motor contactor
- "Check-It" feature displays all float and pump statuses and allows manual pump operation
- Waterproof NEMA 4X Enclosure
- UL 508A listing
- Lockable latch
- Alarm flasher
- Auxiliary alarm contacts
- Redundant off float/low level alarm provision
- Built-in PCB surge protection
- Change configurations: float error ─ redundant pump start, automatic or manual alarm reset, low alarm and seal alarm options
- More options available upon request
Product Specifications
| Specification | Value |
|---|---|
| Application | Simplex NC Pump Systems |
| Frequency | 60 Hz |
| Phases | Three-Phase |
| Voltage | 200 VAC / 230 VAC / 460 VAC |
| SubTrol Heat Sensor | No |
| Installation | Indoor / Outdoor |
| Electrical Agency Approvals | cULus Listed |
| Standard Warranty | 12 Months |
Share